Atmos  |  SKU: 01.04.30-AZ

Wood gasification boiler ATMOS DC30GSE 30 kW log boiler

29.8 kW wood gasification boiler for central log wood heating systems

Automatic wood ignition can be planned via ATMOS ACD 04

Boiler class 5 and energy efficiency class A+

Der Holzvergaserkessel Atmos DC30GSE mit automatischer Zündung ist ein handbeschickter Stückholzkessel für zentrale Heizungsanlagen in Wohngebäuden und vergleichbaren Objekten. Die ACD04-Regelung ermöglicht eine geplante Holzzündung und unterstützt die Einbindung in Anlagen mit Pufferspeicher.

Normal price 7.694,60 €
vAT included. Shipment will be charged at checkout.


Name: Jaroslav Cankař a syn ATMOS

Address: elenského 487 294 21 Bělá pod Bezdězem, Cr

Email: info@atmos-zentrallager.de

Website: https://www.atmos.eu/de/

European Manufacturer: Yes

Highlights

Efficiency 91,3 %
Max. Log Length 530 mm
Draft Requirement 20 Pa
Max. Operating Pressure 2,5 bar
Flue Pipe Connection 150 / 152 mm

Ceramic-lined combustion chamber for controlled wood gasification

Exhaust fan supports flue gas flow during operation

Separately adjustable primary and secondary air

Integration with buffer tank intended for controlled system operation

Thermal drain safety via safety heat exchanger installed

Description

Product Overview & Application

The Atmos DC30GSE with automatic ignition is a wood gasification boiler for central heating of residential buildings and similar properties using dry split logs. With its power class, the boiler is suitable for heating systems where a high-performance log wood heater with a buffer tank and controlled system integration is planned.

The automatic wood ignition supports more convenient operation, as the start of the burn can be scheduled via the control system. This makes the boiler particularly interesting for users who want to use a classic log wood heater but desire more operating comfort when lighting the fire.

Technology & Equipment

The boiler operates on the principle of wood gasification with an induced draft fan. Combustion takes place in a ceramic-lined combustion chamber with preheated primary and secondary air, ensuring controlled burning.

The equipment includes the electronic control unit ATMOS ACD 04. Automatic wood ignition is achieved via a built-in ignition system with an ignition chamber and glow coil. Ignition can be scheduled based on a time program, heating system demand, or buffer tank temperature.

Everyday Benefits

In daily operation, the induced draft fan, controlled air supply, and automatic ignition function make handling the boiler easier. When refueling and during operation, the fan supports flue gas flow, while the control system clearly displays the central operating states of the heating system.

The large loading opening and the ability to use split logs up to 530 mm reduce the effort required for fuel handling. For consistently clean and safe system operation, dry fuel, appropriate return temperature boosting, a buffer tank, and regular cleaning remain crucial.

System Integration & Compatibility

The Atmos DC30GSE with automatic ignition is designed for integration into a water-based heating system. Installation with a buffer tank and return temperature boosting is particularly important for operating a wood gasification boiler, as it keeps the return temperature stable and effectively stores the generated heat.

The ACD04 control system supports system management with a boiler circuit, heating circuits, domestic hot water preparation, and a buffer tank. The specific design of the buffer volume, hydraulics, chimney, and safety devices must be adapted to the respective system.

Technical Specifications at a Glance

The following technical data summarizes the most important verified core specifications of the Atmos DC30GSE with automatic ignition.

Nominal Output 29.8 kW
Fuel Dry split logs
Combustion Technology Wood gasifier / generator gasification
Efficiency 91.3 %
Energy Efficiency Class A+
Max. Flow Temperature 90 °C
Max. Operating Pressure 2.5 bar
Log Length 530 mm
Boiler Class 5
Draft Requirement 20 Pa
Flue Gas Temperature 148 °C
Flue Pipe Connection 150 / 152 mm
Safety Heat Exchanger present
Buffer Tank Recommended yes, at least 55 l per 1 kW of installed boiler output
Ignition System automatic wood ignition with ignition chamber and glow coil
Height 1281 mm
Width 680 mm
Depth 1020 mm
Voltage 230 V
Frequency 50 Hz
Power Consumption 50 W in normal operation / 550 W with ignition on
Weight 466 kg

Installation

Installation is carried out as integration into a water-based heating system with a suitable chimney connection, return temperature boosting, and a buffer tank. Operation requires a sufficiently sized installation room, appropriate combustion air supply, and a professionally coordinated flue gas routing.

Installation, commissioning, and instruction should be carried out by a qualified specialist company. Hydraulic integration, electrical connections, thermal safety drain, and chimney conditions must match the respective system.

Notes

The boiler is intended for dry split logs. For clean operation and a long service life, firewood with an appropriate moisture content must be used.

For wood gasification boilers, return temperature, buffer tank, regular cleaning, and correctly adjusted combustion air are important prerequisites for reliable system operation. The specific power selection does not replace a heat load calculation.

Scope of Delivery

  • Atmos DC30GSE wood gasification boiler with automatic ignition
  • Steel brush with accessories
  • Poker
  • Fill valve
  • Operating and maintenance manual
  • Draft regulator Honeywell FR 124
  • Ash pan
  • Device for pulling the braking devices out of the flue gas channel
  • Accessory set for the ACD 04 controller
  • 1 outdoor temperature sensor AF20-B65
  • 3 pipe contact sensors SF20-B54
  • 3 domestic hot water and buffer tank sensors KTF20-65-5M-B
  • Blind chamber, removable
  • Pellet filling shovel

payment & Security

Payment options

  • American Express
  • Apple Pay
  • Bancontact
  • BLIK
  • EPS
  • Google Pay
  • iDEAL Wero
  • Klarna
  • Maestro
  • Mastercard
  • MobilePay
  • PayPal
  • Przelewy24
  • Shop Pay
  • Union Pay
  • Visa

Your payment information is processed securely. We do not store or access your credit card information.

Contact us